FloorPeel 4000 |
|
|
|
|
| |
This product is a strippable
coating
for floors and provides temporary
protection for floors with heavy
traffic. |
|
|
|
|
| |
When Cured: Water resistant,
alkali resistant and heat
resistant. |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| |
| FloorPeel 4000 is a
temporary Protective Floor Strippable coating and Floor
peelable coating formulated for maintenance of industrial
floors. It protects floors form build-up of inks, spray
track adhesives, paint tracks, lint, grease and grime. When
it is time to clean, just peel it up. |
|
| FloorPeel Black: This product is
black pigmented and used by
photographic studios and other applications where
they need to have a black floor. This helps avoid the need
to paint the floor black. |
|
| |
Designed especially for floors, it
has built in traction allowing you to walk on it and avoid slippage.
4000 films are tough and durable to handle heavy forklift and foot
traffic. Perfect for floor areas around presses, spray areas, high
traffic routes. |
 |
| Floorpeel 4000 |
| For Heavy Traffic
Floors |
|
|
|
| |
It is easy to apply and very easy to
peel. Maintenance costs with 4000 are reduced and floors are maintained in
brand new condition. . FloorPeel 4000 has no VOC's |
|
|
|
|
| |
Easily strippable 4000 allows easy
maintenance for any Industrial Floors. |
|
|
|
|
| |
Booth Coat 5201 represents the
ultimate in non-solvent strippable coating. It is well stabilized against
brittleness and it will not be softened or penetrated by solvent-based
paints. |
|
|
|
|
| |
FloorPeel 4000 can be used on
concrete, tile, glass, ceramic, laminates, brick, and many other non-porous
clean surfaces such as : |
|
|
|
|
| |
|
Concrete floors-painted
or sealed |
|
Tile Floors-with sealed grout |
|
Wood floors-seal bare wood floors first to
prevent pulling up wood fibers |
|
Laminate flooring |
|
Brick Floors-Apply
sealant first |
|
Steel, aluminum, brass, copper and other
ferrous and non ferrous metals |
|
Glass, plastic and acrylics like Lexan |
|
Other non-porous or well sealed floor
materials. |
|
|
|
|
|
|
|
|
| |
 |
Introduction:
Floor protection, Floor Coating and
Temporary Protective Peelable Coating |
|
|
|
|
|
| |
General Chemical's
Floorpeel 4000 is a clear water resistant, peelable temporary protective
coating which has many applications. It can be used to protect various types
of surfaces during industrial processing. Floorpeel 4000 air dries quickly,
leaving a tough, clear flexible coating that is easily removed from a
variety of surfaces. FloorPeel 4000 represents the ultimate in waterborne
removable coating technology. It is stabilized against brittleness and is
not softened or penetrated by most water-based compounds. |
|
|
|
|
| |
Floorpeel 4000 is good
over cement, linoleum and floor painted with enamels that are resistant to
water. Floorpeel 4000 will adhere to enamels based on emulsions and
therefore should not be used. |
|
| |
:
1. We are a fiberglass manufacturer and am looking for a floor and wall
coating that can be easily removed from our gel coat and chop booths. Any
ideas? John Project Manager
Our Recommendations :For the floor our FloorPeel 4000 will be exactly
what you need especially if you have heavy foot traffic and fork truck
traffic running over it. This is a water based, zero VOC content peelable
coating that has a built in non slip feature. The soiled area can be cut
out, peeled up and reapplied or simply peel the entire area and recoat.. One
gallon will cover approx 100 to 125 square feet. |
|
|
|
|
|
|
|
|
|
|
| |
 |
Benefits To You :
Floor protection, floor coating and temporary protective coating |
|
|
| |
|
No Flash point Water
Based for environment and worker safety |
|
Durable peelable coating with Built in
Traction for avoiding slippage |
|
Keeps everything underneath clean |
|
|
|
|
|
|
|
|
| |
 |
Application:
Floor protection, floor coating and temporary protective coating |
|
|
|
|
|
| |
FloorPeel 4000 should
be used as received. It can be applied by airless spray, paint roller, or
brush. The coating dries upon water evaporation. Wet coating is milky
(white). Dry coating is clear. The surface to be applied with FloorPeel 4000
should be dry, clean and free from oil, grease and other water incompatible
matter. The clean surface helps even distribution of FloorPeel 4000. The
surface remains clean when FloorPeel 4000 is removed and surface clean up
will not be necessary for second time application. FloorPeel 4000 should be
applied to form a dry film in the range of 3 to 10 mils(.003" to .010")
thick. Application temperature is ambient to no lower than 50ºF. Drying
times will be affected by humidity, film thickness, air movement and
temperature. Best time to apply is on week-ends or late afternoons to give a
coating time to dry. Proper fan placement can speed the dry by removing
water at a much faster rate. Application by roller might require a few
coats. Thick coating peels in one large continuous sheet. Thin coating will
break in areas of coating weakness. FloorPeel 4000 is water based for safe
use and easy water clean up. Dry coating are water resistant. When applying
FloorPeel 4000 use the same protection as used while applying paint.. |
|
|
|
|
|
|
|
|
|
|
| |
 |
Precautions:
Floor protection, floor coating and temporary protective coating |
|
|
|
|
|
| |
Always test a small
inconspicuous area first. Because of various substrate characteristics and
conditions like porosity, deterioration, embattlement, adverse wear area,
type of ink, paint and or other coating applied, abrasion of panted
surfaces, and the like ,it is difficult to predetermine specific effects
from this product. |
|
|
|
|
|
|
|
| |
 |
Safety & Handling
Floor protection, floor coating and temporary protective coating |
|
|
|
|
|
| |
See application and
safety precautions before applying. Liquid product is slippery when wet.
Please refer to MSDS. |
|
|
|
|
|
|
|
| |
 |
Recommendations:
Floor protection, floor coating and temporary protective coating |
|
|
| |
| 1.outline your floor area to be protected
with the self adhesive fiber tape. DO not overlap tap edges ,but
keep adjacent |
| 2.for best results, wet roller with water
and squeeze out excess water. For best overall results Floorpeel
should be applied to a minimum of dry mils |
| 3.apply FloorPeel 4000 and let it dry.
Rinse out roller with plenty of water between coats |
| 4.Allow first coat to dry. dry time will be
affected by coating thickness, application methods, humidity and air
flow in the vicinity. Initial drying time is 30 minutes
approximately. |
| 5.Apply second coat and allow it to dry
before permitting traffic on the floor. |
|
|
|
|
|
|
|
|
|
 |
Curing:
Floor protection, floor coating and temporary protective coating |
|
|
| |
FloorPeel 4000 cures
upon water evaporation. Dry time is dependent upon temperature, humidity,
air movement and thickness of the coating. Curing may be accelerated by
forced dry air up to 100 degrees Fahrenheit. Force dry coating can cure in
less than 10 minutes. Most coating without assist will dry in a few hours.
It is imperative that FloorPeel 4000 be thoroughly cured and dry, before an
attempt is made to peel the coating from the substrate. Cured coating is
clear throughout. Cured FloorPeel 4000 is water resistant. Floors coated
with FloorPeel 4000 can be water mopped. |
|
|
|
|
|
|
|
|
|
|
|
 |
Storage:
Floor protection, floor coating and temporary protective coating |
|
|
|
|
|
| |
FloorPeel 4000 should
be stored in the original shipping container with temperatures between 60
and 90 degrees F. Container should be sealed until needed. Protection from
freezing is necessary. |
|
|
|
|
|
|
|
|
 |
Removal: |
|
|
|
|
|
| |
4000 is readily removed
from surfaces by peeling any exposed edge. This peelable coating can be
removed by prying an edge and slowly lifting the coating off the floor. |
|
|
|
|
|
|
|
| |
 |
Physical Characteristics: |
|
|
|
|
|
| |
Color:
White when wet. Clear when dry.
Weight: 9.92 Lbs./Gallon
Viscosity: 50-60" on Zahn #2 cup at 77 degrees
Fahrenheit
Flashpoint: None
|
|
|
|
|
|
|
|
| |
 |
Operating Guidelines: |
|
|
|
|
|
| |
1.When applying, use
the same protection as used while applying paint. Provide ventilation.
|
|
|
|
|
| |
2.Chemical goggles,
impervious gloves and respirators should be worn when handling 4000. |
|
|
|
|
| |
3.The use of
non-sparking equipment is advised if scraping becomes necessary. |
|
|
|
|
|
|
|
| |
 |
Testimonials: |
|
|
|
|
|
| |
"I've found Floorpeel
to be the best solution for a quick and easy clean up for our new spray
booth! Easy to apply and remove. Thanks General Chemical!" Sincerely D.
Craig Jones.
|
|
|
|
|
| |
Some Equipment Notes:
|
|
|
|
|
| |
Airless System:
Recommended tip size is .070, similar to a glue tip. |
|
|
|
|
| |
Note:
The information presented herein is our interpretation of certain test
results and field experience to date. The information is not to be taken as
warranty or representation for which we assume legal responsibility, nor as
permission or recommendation to practice any patented invention without a
license. It is offered solely for your consideration, investigation and
verification. |
|
|
|
|
|
|
|
|
| Top Floor protection, Floor