|
|
|
|
|
|
| |
Floor strippable coating, Peelable coating for Floors and Temporary Protective Peelable coating for floor with Heavy traffic, Photographic studio. |
|
|
|
|
| |
When Cured: water Resistant, Alkali resistant and Heat Resistant |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| |
| FloorPeel_4000 is a temporary Protective Floor Strippable Coatings and Floor Peelable Coatings formulated for maintenance of industrial floors. It protects floors form build-up of inks, spray track adhesives, paint tracks, lint, grease and grime. When it is time to clean, just peel it up. |
|
| FloorPeel Black: This product is black pigmented and used by photographic studios and in other application where they need to have a black floor. This helps avoid the need to paint the floor black. |
|
| |
|
 |
| FloorPeel_4000 |
| For Heavy Traffic Floors |
|
|
|
|
|
|
| |
Designed especially for floors, I has built in traction to walk on it and avoid slippage. 4000 films are tough and durable to handle heavy forklift and foot traffic. Perfect for floor areas around presses, spray areas, high traffic routes. |
|
|
|
|
| |
It is easy to apply and very easy to peel. Maintenance costs with 4000 are reduced and floors are maintained in brand new condition. . FloorPeel 4000 has no VOC's |
|
|
|
|
| |
Easily strippable 4000 allows easy maintenance for any Industrial Floors. |
|
|
|
|
| |
Booth Coat 5201 represents the ultimate in non-solvent strippable coatings. It is well stabilized against brittleness and it will not be softened or penetrated by solvent-based paints. |
|
|
|
|
| |
FloorPeel 4000 can be used on concrete, tile, glass, ceramic, laminates, brick, and many other non-porous clean surfaces such as : |
|
|
|
|
| |
|
Concrete floors-painted or sealed |
|
Tile Floors-with sealed grout |
|
Wood floors-seal bare wood floors first to prevent pulling up wood fibers |
|
Laminate flooring |
|
Brick Floors-Apply sealant first |
|
Steel, aluminum, brass, copper and other ferrous and non ferrous metals |
|
Glass, plastic and acrylics like Lexan |
|
Other non-porous or well sealed floor materials. |
|
|
|
|
|
|
|
|
|
|
|
| |
 |
Introduction: Floor protection, floor coating and temporary protective coating |
|
|
|
|
|
| |
General Chemical's FloorPeel_4000 is a CLEAR water resistant, Peelable temporary protective coating which has many applications. It can be used to protect various types of surfaces during industrial processing. FloorPeel_4000 air dries quickly, leaving a tough, clear flexible coating that is easily removed from a variety of surfaces. FloorPeel 4000 represents the ultimate in waterborne removable coating technology. It is stabilized against brittleness and is not softened or penetrated by most water-based compounds. |
|
|
|
|
| |
Floorpeel 4000 is good over cement, linoleum and floor painted with enamels that are resistant to water. Floorpeel 4000 will adhere to enamels based on emulsions and therefore should not be used. |
|
|
|
|
|
|
|
|
|
|
|
 |
Description: |
|
|
|
|
|
|
 |
Products |
|
 |
Peelable Coating Special Features |
|
|
|
Floor strippable coating, Peelable coating for Floors and Temporary Protective Peelable coating for floor with Heavy traffic, Photographic studio. |
|
Represents the ultimate in non-solvent strippable coatings. It is well stabilized against brittleness and it will not be softened or penetrated by solvent-based paints. |
|
|
|
|
|
|
|
|
| |
 |
Benefits To You : Floor protection, floor coating and temporary protective coating |
|
|
|
|
|
| |
|
No Flash point Water Based for environment and worker safety
|
|
Durable Peelable coating with Built in Traction for avoiding slippage |
|
Keeps everything underneath clean |
|
|
|
|
|
|
|
|
|
|
|
| |
 |
Application: Floor protection, floor coating and temporary protective coating |
|
|
|
|
|
| |
|
|
|
|
|
| |
FloorPeel 4000 should be used as received. It can be applied by airless spray, paint roller, or brush. The coating dries upon water evaporation. Wet coating is milky (white). Dry coating is clear. The surface to be applied with FloorPeel 4000 should be dry, clean and free from oil, grease and other water incompatible matter. The clean surface helps even distribution of FloorPeel 4000. The surface remains clean when FloorPeel 4000 is removed and surface clean up will not be necessary for second time application. FloorPeel 4000 should be applied to form a dry film in the range of 3 to 10 mils(.003" to .010") thick. Application temperature is ambient to no lower than 50ºF. Drying times will be affected by humidity, film thickness, air movement and temperature. Best time to apply is on week-ends or late afternoons to give a coating time to dry. Proper fan placement can speed the dry by removing water at a much faster rate. Application by roller might require a few coats. Thick coating peels in one large continuous sheet. Thin coatings will break in areas of coating weakness. FloorPeel 4000 is water based for safe use and easy water clean up. Dry coatings are water resistant. When applying FloorPeel 4000 use the same protection as used while applying paint.. |
|
|
|
|
| |
 |
Precautions: Floor protection, floor coating and temporary protective coating |
|
|
|
|
|
| |
Always test a small inconspicuous area first. Because of various substrate characteristics and conditions like porosity, deterioration, embattlement, adverse wear area, type of ink, paint and or other coatings applied, abrasion of panted surfaces, and the like ,it is difficult to predetermine specific effects from this product. |
|
|
|
|
| |
 |
Safety & Handling :Floor protection, floor coating and temporary protective coating |
|
|
|
|
|
| |
See application and safety precautions before applying. Liquid product is slippery when wet. Please refer to MSDS. |
|
|
|
|
| |
 |
Recommendations :Floor protection, floor coating and temporary protective coating |
|
|
|
|
|
| |
| 1.Outline your floor area to be protected with the self adhesive fiber tape. DO not overlap tap edges ,but keep adjacent. |
| 2.For best results, wet roller with water and squeeze out excess water. For best overall results Floorpeel should be applied to a minimum of dry mils |
| 3.Apply FloorPeel 4000 and let it dry. Rinse out roller with plenty of water between coats |
| 4.Allow first coat to dry. dry time will be affected by coating thickness, application methods, humidity and air flow in the vicinity. Initial drying time is 30 minutes approximately. |
| 5.Apply second coat and allow it to dry before permitting traffic on the floor. |
|
|
|
|
|
|
 |
Curing:Floor protection, floor coating and temporary protective coating |
|
|
|
|
|
| |
FloorPeel 4000 cures upon water evaporation. Dry time is dependent upon temperature, humidity, air movement and thickness of the coating. Curing may be accelerated by forced dry air up to 100 degrees Fahrenheit. Force dry coatings can cure in less than 10 minutes. Most coatings without assist will dry in a few hours. It is imperative that FloorPeel 4000 be thoroughly cured and dry, before an attempt is made to peel the coating from the substrate. Cured coating is clear throughout. Cured FloorPeel 4000 is water resistant. Floors coated with FloorPeel 4000 can be water mopped. |
|
|
|
|
|
 |
Storage:Floor protection, floor coating and temporary protective coating |
|
|
|
|
|
| |
FloorPeel 4000 should be stored in the original shipping container with temperatures between 60 and 90 degrees F. Container should be sealed until needed. Protection from freezing is necessary. |
|
|
|
|
|
 |
Removal: |
|
|
|
|
|
| |
4000 is readily removed from surfaces by peeling any exposed edge. This Peelable coating can be removed by prying an edge and slowly lifting the coating off the floor. |
|
|
|
|
|
|
|
|
|
|
| |
 |
Physical Characteristics: |
|
|
|
|
|
| |
Color: White when wet. Clear when dry.
Weight: 9.92 Lbs./Gallon
Viscosity: 50-60" on Zahn #2 cup at 77 degrees Fahrenheit
Flashpoint: None
|
|
|
|
|
|
|
|
|
|
|
| |
 |
Operating Guidelines: |
|
|
|
|
|
| |
1.When applying, use the same protection as used while applying paint. Provide
ventilation.
|
|
|
|
|
| |
2.Chemical goggles, impervious gloves and respirators should be worn when handling
4000. |
|
|
|
|
| |
3.The use of non-sparking equipment is advised if scraping becomes necessary. |
|
|
|
|
|
|
|
|
|
|
| |
 |
Testimonials: |
|
|
|
|
|
| |
"I've found Floorpeel to be the best solution for a quick and easy clean up for our new spray booth! Easy to apply and remove. Thanks General Chemical!" Sincerely D. Craig Jones.
|
|
|
|
|
|
|
|
|
|
|
| |
 |
Some Equipment Notes: |
|
|
|
|
|
| |
Airless System: Recommended tip size is .070, similar to a glue tip. |
|
|
|
|
| |
Note: The information presented herein is our interpretation of certain test results and field experience to date. The information is not to be taken as warranty or representation for which we assume legal responsibility, nor as permission or recommendation to practice any patented invention without a license. It is offered solely for your consideration, investigation and verification. |
|
|
|
|
|
|
|
|
|
|